Stetho Cases

Recordings and measurements: the data behind Stetho Cases

Stetho Cases uses 1,904 cases built on 1,516 audio clips from five openly licensed collections. Heart cases are children’s recordings kept only when the label and a measurement agree; lung cases hold one clearly labelled kind of sound. Reference sounds come from a teaching library and a manikin and are named as such.

Collections

CollectionRecorded fromCasesLicence
CirCor DigiScopeReal patient (child)458ODC-By 1.0
SPRSoundReal patient (child)586CC BY 4.0
HF_Lung_V1Real patient (adult)682CC BY 4.0
University of Michigan Heart Sound and Murmur LibraryTeaching recording94CC BY-SA 4.0
HLS-CMDSTeaching manikin84CC BY 4.0

What we measured in the lung clips

LabelClipsMarksStrongest frequency, median (middle half)Centroid, medianMark length, median
Normal150150133 Hz (117–156)269 Hzwhole clip
Wheeze235588180 Hz (133–227)217 Hz0.71 s
Rhonchi186492117 Hz (102–133)152 Hz0.75 s
Crackles (any)262809148 Hz (125–188)230 Hz0.92 s
Fine crackles150390141 Hz (125–164)196 Hz1.00 s
Coarse crackles2947133 Hz (125–148)170 Hz1.33 s
Stridor2446145 Hz (125–186)182 Hz1.18 s

Method. Each stretch marked by the dataset annotators was cut from the clip shipped in the app, resampled to 8 kHz, and its average power spectrum taken with a 1,024-point Hann window between 80 and 2,000 Hz. “Strongest frequency” is the highest bin (about 8 Hz wide). The clips were already filtered and level-adjusted, come from two collections with different microphones, and were chosen for clear labels, so these numbers describe this set, not all patients. Stridor and coarse crackles are small groups. A mark can hold many crackles; its length is not the length of one crackle.

Heart clips

In the 122 clips with a systolic murmur, the heart rate worked out from the labelled systoles has a median of 103 beats per minute (10th to 90th percentile 83–117), which is why systole and diastole sound almost equally long in many of them.

Limits

Sources

  1. Oliveira J, Renna F, Costa P, et al. The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification. IEEE Journal of Biomedical and Health Informatics. 2022;26:2524-2535.
  2. Zhang Q, et al. SPRSound: Open-Source SJTU Paediatric Respiratory Sound Database. IEEE Transactions on Biomedical Circuits and Systems. 2022;16:867-881.
  3. Hsu FS, Huang SR, Huang CW, et al. Benchmarking of eight recurrent neural network variants for breath phase and adventitious sound detection: HF_Lung_V1. PLOS ONE. 2021;16:e0254134.
  4. Judge R, Mangrulkar R. Heart Sound and Murmur Library. University of Michigan, Open.Michigan, 2015.
  5. Torabi Y, Shirani S, Reilly JP. HLS-CMDS: Heart and Lung Sounds Dataset Recorded from a Clinical Manikin. UCI Machine Learning Repository, 2025.