Stridor vs wheeze: difference, with audio
Stridor comes from the upper airway, is usually heard on inspiration and is loudest over the neck. Wheeze comes from airways inside the chest, is usually heard on expiration and is loudest over the chest. Both are continuous, musical sounds, so phase and place tell them apart better than pitch.
Listen to both
2000 HzSource: SPRSound, CC BY 4.0; cut, filtered and levelled.
2000 HzSource: SPRSound, CC BY 4.0; cut, filtered and levelled.
Side by side
| Stridor | Wheeze | |
|---|---|---|
| Source | Larynx, trachea | Airways in the chest |
| Usual phase | Inspiration | Expiration |
| Loudest | Over the neck | Over the chest |
| Heard without a stethoscope | Often | Sometimes |
| Typical causes | Croup, foreign body, epiglottitis | Asthma, COPD, bronchiolitis |
Learn each one
Sources
- Zhang Q, et al. SPRSound: Open-Source SJTU Paediatric Respiratory Sound Database. IEEE Transactions on Biomedical Circuits and Systems. 2022;16:867-881.
- Bohadana A, Izbicki G, Kraman SS. Fundamentals of Lung Auscultation. New England Journal of Medicine. 2014;370:744-751.
- Pasterkamp H, Brand PLP, Everard M, et al. Towards the standardisation of lung sound nomenclature. European Respiratory Journal. 2016;47:724-732.
- Hsu FS, Huang SR, Huang CW, et al. Benchmarking of eight recurrent neural network variants for breath phase and adventitious sound detection: HF_Lung_V1. PLOS ONE. 2021;16:e0254134.